LMI Metering Pump PD741-822SI .5 GPH, 250 psi, PVDF, Manual/Pulse Control
LMI's [ PD741-822SI ] PD Series - solenoid driven, electronic metering pump for chemical feed up to [ 0.68 GPH (2.6 LPH) ] and pressure up to [ 250.0 psi (17.2 bar) ] uses the [ PD741 ] drive end with [ Manual (Stroke Frequency) & Remote (Pulse Input) ] control and [ Standard US 115V ] power cord. The [ LE-822SI ] liquid end - with [ 57710 ] Multi-Function Valve contains a [ PVDF (Kynar) ] head, [ PVDF (Kynar) ] fittings, [ PTFE (Teflon) & Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Replaces [ A111-812SI, A141-812SI, A711-812SI, A741-812SI, P721-352SI, P741-352SI ]; Repair Kit [ RPM-822 ]; Multi-Function Valve [ 57707 Retrofit or 57710 Replacement ]
LMI Metering Pump PD751-832SI 1 GPH, 110 psi, PVDF, Manual/Pulse Control
LMI's [ PD751-832SI ] PD Series - solenoid driven, electronic metering pump for chemical feed up to [ 1.1 GPH (4.2 LPH) ] and pressure up to [ 150.0 psi (10.2 bar) ] uses the [ PD751 ] drive end with [ Manual (Stroke Frequency) & Remote (Pulse Input) ] control and [ Standard US 115V ] power cord. The [ LE-832SI ] liquid end - with [ 57708 ] Multi-Function Valve contains a [ PVDF (Kynar) ] head, [ PVDF (Kynar) ] fittings, [ Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Replaces [ A151-822SI, A751-822SI ]; Repair Kit [ RPM-832 ]; Multi-Function Valve [ 57706 Retrofit or 57708 Replacement ]
LMI Pump AD941-925SI Series AD Chemical Metering Pump, 0.5 GPH, 250 Max PSI, 50/60 Hz, 115 Volt with Dual Manual Control and 4-20mA Control
LMI's [ AD941-925SI ] Excel AD - solenoid driven, electronic metering pump for chemical feed up to [ 0.5 GPH (1.9 LPH) ] and pressure up to [ 250.0 psi (17.2 bar) ] uses the [ AD941 ] drive end with [ Manual (Stroke Volume + Frequency) & Remote (Pulse + 4-20mA Inputs) ] control and [ Standard US 115V ] power cord. The [ LE-925SI ] liquid end - with [ 57711 ] Multi-Function Valve contains a [ Polypropylene ] head, [ Polypropylene ] fittings, [ PTFE (Teflon) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Repair Kit [ RPM-823 ]; Multi-Function Valve [ 57707 Retrofit or 57711 Replacement ]
LMI Pump Autoprime C121-D68HI. 4FV 3/8″ tubing. 4.0 GPH 100 PSI. for degasing Chemicals Like Bleach
LMI's [ C121-D68HI ] C Series - solenoid driven, electronic metering pump for chemical feed up to [ 3.8 GPH (14.4 LPH) ] and pressure up to [ 100.0 psi (6.9 bar) ] uses the [ C121 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-D68HI ] liquid end - with [ 58062 ] Machined Multi-Function Valve contains a [ PVC ] head, [ PVC ] fittings, [ Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Repair Kit [ RPM-D68 ]; Machined Multi-Function Valve [ 58060 Retrofit or 58062 Replacement ]
LMI Pump B121-85HV. Made for High Viscosity Liquids. 2.5 GPH / 100 PSI. PP Head and Fittings
LMI's [ B121-85HV ] B Series - solenoid driven, electronic metering pump for chemical feed up to [ 2.5 GPH (9.5 LPH) ] and pressure up to [ 100.0 psi (6.9 bar) ] uses the [ B121 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-85HV ] liquid end contains a [ Polypropylene ] head, [ Polypropylene ] fittings, [ PTFE (Teflon) ] seals, and [ 316 Stainless Steel ] check valve balls // LMI Pump Reference: Replaces [ B121-85HP ]; Repair Kit [ SP-85HV ]
LMI Pump B121-D98HI. Autoprime Pump for degasing Bleach. 2.3 GPH / 100 PSI 4FV 3/8″ tubing.
LMI's [ B121-D98HI ] B Series - solenoid driven, electronic metering pump for chemical feed up to [ 2.3 GPH (8.7 LPH) ] and pressure up to [ 100.0 psi (6.9 bar) ] uses the [ B121 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-D98HI ] liquid end - with [ 58062 ] Machined Multi-Function Valve contains a [ PVC ] head, [ PVC ] fittings, [ Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Repair Kit [ RPM-D98 ]; Machined Multi-Function Valve [ 58060 Retrofit or 58062 Replacement ]
LMI Pump C121-75HV. High Viscosity Pump. PP Head and Fittings. 4.0 GPH / 100 PSI
LMI's [ C121-75HV ] C Series - solenoid driven, electronic metering pump for chemical feed up to [ 4.0 GPH (15.1 LPH) ] and pressure up to [ 100.0 psi (6.9 bar) ] uses the [ C121 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-75HV ] liquid end contains a [ Polypropylene ] head, [ Polypropylene ] fittings, [ PTFE (Teflon) ] seals, and [ 316 Stainless Steel ] check valve balls // LMI Pump Reference: Replaces [ C121-75HP ]; Repair Kit [ SP-75HV ]
LMI Pump C131-26S. 4FV 1/2″ Tubing. 8.0 GPH / 60 PSI. PVC Head and Fittings.
LMI's [ C131-26S ] C Series - solenoid driven, electronic metering pump for chemical feed up to [ 8.0 GPH (30.0 LPH) ] and pressure up to [ 60.0 psi (4.1 bar) ] uses the [ C131 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-26S ] liquid end contains a [ PVC ] head, [ PVC ] fittings, [ FKM (Viton) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Repair Kit [ SP-26 ]
LMI Pump Model AD241-822SI .5gph/250 psi Max 4FV 1/4″ OD Tubing and Connections
LMI's [ AD241-822SI ] Excel AD - solenoid driven, electronic metering pump for chemical feed up to [ 0.5 GPH (1.9 LPH) ] and pressure up to [ 250.0 psi (17.2 bar) ] uses the [ AD241 ] drive end with [ Manual (Stroke Volume + Frequency) ] control and [ Standard US 115V ] power cord. The [ LE-822SI ] liquid end - with [ 57710 ] Multi-Function Valve contains a [ PVDF (Kynar) ] head, [ PVDF (Kynar) ] fittings, [ PTFE (Teflon) & Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Repair Kit [ RPM-822 ]; Multi-Function Valve [ 57707 Retrofit or 57710 Replacement ]
LMI Pump Model B111-392SI. 4FV. 1.6gph/150psi max.375″ OD tubing and Connections. Includes Injection Valve, Foot Valve, Weight, and tubing.
LMI's [ B111-392SI ] B Series - solenoid driven, electronic metering pump for chemical feed up to [ 1.6 GPH (6.1 LPH) ] and pressure up to [ 150.0 psi (10.3 bar) ] uses the [ B111 ] drive end with [ Manual (Stroke Volume) ] control and [ Standard US 115V ] power cord. The [ LE-392SI ] liquid end - with [ 57708 ] Multi-Function Valve contains a [ PVDF (Kynar) ] head, [ PVDF (Kynar) ] fittings, [ PVDF (Kynar) & Polyprel (TFE/P - Aflas) ] seals, and [ Ceramic ] check valve balls // LMI Pump Reference: Replaces [ B111-392SP, B111-392TI, B111-392TP ]; Repair Kit [ RPM-392/398 ]; Multi-Function Valve [ 57706 Retrofit or 57708 Replacement ]